The BHC3 controller is designed as an economical device to control radiant heating pumps or attic fans. The controller is activated by an industry standard 2-wire thermostat or on/off switch. |
Specification:
-120 VAC 63Hz
-Maximum sump pump load 25A on start ups and up to 15A continuous run
-Power consumption 0.6W at standby, and 2W when pump is on (cost of running, up to 10 cents per month)
-Loud 105 dB sound alarm (105 dB sound is 100 times more intense than 85 dB)
-Three Super Bright LED indicators
-one standard 120 VAC socket
-100.000 on/off cycles
-25 Amp contact rating
-Three-year warranty
-2.8 feet AC cord
-Tie - ups for securing AC cable and control cables
-5 foot long sensor wires (length can be easy extended)
Included: control box with mounting bracket, leak water sensor and mounting screws. Priced at $72.